FlexSCADA DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI enterprises FROM RFC1155-SMI DisplayString FROM RFC1213-MIB TEXTUAL-CONVENTION FROM SNMPv2-TC OBJECT-GROUP FROM SNMPv2-CONF; FlexSCADA MODULE-IDENTITY LAST-UPDATED "202003060000Z" ORGANIZATION "FlexSCADA" CONTACT-INFO "FlexSCADA Systems Postal: COM COM SERVICES LTD. 281 MAINSTREET (UPSTAIRS) LYTTON, BC V0K1Z0 CANADA Tel: +1 877 825 1530 E-Mail: info@flexscada.com" DESCRIPTION "FlexSCADA Product: Flexs Q5 Copyright (C) FlexSCADA (2020). All Rights Reserved" REVISION "202003060000Z" DESCRIPTION "Original version" ::= { enterprises 55274 } Q5 OBJECT IDENTIFIER ::= { FlexSCADA 0 } analogInputs OBJECT IDENTIFIER ::= { Q5 0 } loadSwitches OBJECT IDENTIFIER ::= { Q5 2 } customFeeds OBJECT IDENTIFIER ::= { Q5 4 } tempSensors OBJECT IDENTIFIER ::= { Q5 8 } powerMetrics OBJECT IDENTIFIER ::= { Q5 10 } chargeControllers OBJECT IDENTIFIER ::= { Q5 11 } in1 OBJECT IDENTIFIER ::= { analogInputs 1 } avg OBJECT IDENTIFIER ::= { in1 0 } inst OBJECT IDENTIFIER ::= { in1 1 } min OBJECT IDENTIFIER ::= { in1 2 } max OBJECT IDENTIFIER ::= { in1 3 } discrete OBJECT IDENTIFIER ::= { in1 4 } ripple OBJECT IDENTIFIER ::= { in1 5 } in2 OBJECT IDENTIFIER ::= { analogInputs 2 } avg OBJECT IDENTIFIER ::= { in2 0 } inst OBJECT IDENTIFIER ::= { in2 1 } min OBJECT IDENTIFIER ::= { in2 2 } max OBJECT IDENTIFIER ::= { in2 3 } discrete OBJECT IDENTIFIER ::= { in2 4 } ripple OBJECT IDENTIFIER ::= { in2 5 } in3 OBJECT IDENTIFIER ::= { analogInputs 3 } avg OBJECT IDENTIFIER ::= { in3 0 } inst OBJECT IDENTIFIER ::= { in3 1 } min OBJECT IDENTIFIER ::= { in3 2 } max OBJECT IDENTIFIER ::= { in3 3 } discrete OBJECT IDENTIFIER ::= { in3 4 } ripple OBJECT IDENTIFIER ::= { in3 5 } in4 OBJECT IDENTIFIER ::= { analogInputs 4 } avg OBJECT IDENTIFIER ::= { in4 0 } inst OBJECT IDENTIFIER ::= { in4 1 } min OBJECT IDENTIFIER ::= { in4 2 } max OBJECT IDENTIFIER ::= { in4 3 } discrete OBJECT IDENTIFIER ::= { in4 4 } ripple OBJECT IDENTIFIER ::= { in4 5 } in5 OBJECT IDENTIFIER ::= { analogInputs 5 } avg OBJECT IDENTIFIER ::= { in5 0 } inst OBJECT IDENTIFIER ::= { in5 1 } min OBJECT IDENTIFIER ::= { in5 2 } max OBJECT IDENTIFIER ::= { in5 3 } discrete OBJECT IDENTIFIER ::= { in5 4 } ripple OBJECT IDENTIFIER ::= { in5 5 } in6 OBJECT IDENTIFIER ::= { analogInputs 6 } avg OBJECT IDENTIFIER ::= { in6 0 } inst OBJECT IDENTIFIER ::= { in6 1 } min OBJECT IDENTIFIER ::= { in6 2 } max OBJECT IDENTIFIER ::= { in6 3 } discrete OBJECT IDENTIFIER ::= { in6 4 } ripple OBJECT IDENTIFIER ::= { in6 5 } in7 OBJECT IDENTIFIER ::= { analogInputs 7 } avg OBJECT IDENTIFIER ::= { in7 0 } inst OBJECT IDENTIFIER ::= { in7 1 } min OBJECT IDENTIFIER ::= { in7 2 } max OBJECT IDENTIFIER ::= { in7 3 } discrete OBJECT IDENTIFIER ::= { in7 4 } ripple OBJECT IDENTIFIER ::= { in7 5 } in8 OBJECT IDENTIFIER ::= { analogInputs 8 } avg OBJECT IDENTIFIER ::= { in8 0 } inst OBJECT IDENTIFIER ::= { in8 1 } min OBJECT IDENTIFIER ::= { in8 2 } max OBJECT IDENTIFIER ::= { in8 3 } discrete OBJECT IDENTIFIER ::= { in8 4 } ripple OBJECT IDENTIFIER ::= { in8 5 } sw1 OBJECT IDENTIFIER ::= { loadSwitches 1 } state OBJECT IDENTIFIER ::= { sw1 0 } loadCurrent OBJECT IDENTIFIER ::= { sw1 1 } loadPower OBJECT IDENTIFIER ::= { sw1 2 } hvdTrip OBJECT IDENTIFIER ::= { sw1 3 } lvdTrip OBJECT IDENTIFIER ::= { sw1 4 } fuseTrip OBJECT IDENTIFIER ::= { sw1 5 } sw2 OBJECT IDENTIFIER ::= { loadSwitches 2 } state OBJECT IDENTIFIER ::= { sw2 0 } loadCurrent OBJECT IDENTIFIER ::= { sw2 1 } loadPower OBJECT IDENTIFIER ::= { sw2 2 } hvdTrip OBJECT IDENTIFIER ::= { sw2 3 } lvdTrip OBJECT IDENTIFIER ::= { sw2 4 } fuseTrip OBJECT IDENTIFIER ::= { sw2 5 } sw3 OBJECT IDENTIFIER ::= { loadSwitches 3 } state OBJECT IDENTIFIER ::= { sw3 0 } loadCurrent OBJECT IDENTIFIER ::= { sw3 1 } loadPower OBJECT IDENTIFIER ::= { sw3 2 } hvdTrip OBJECT IDENTIFIER ::= { sw3 3 } lvdTrip OBJECT IDENTIFIER ::= { sw3 4 } fuseTrip OBJECT IDENTIFIER ::= { sw3 5 } sw4 OBJECT IDENTIFIER ::= { loadSwitches 4 } state OBJECT IDENTIFIER ::= { sw4 0 } loadCurrent OBJECT IDENTIFIER ::= { sw4 1 } loadPower OBJECT IDENTIFIER ::= { sw4 2 } hvdTrip OBJECT IDENTIFIER ::= { sw4 3 } lvdTrip OBJECT IDENTIFIER ::= { sw4 4 } fuseTrip OBJECT IDENTIFIER ::= { sw4 5 } sw5 OBJECT IDENTIFIER ::= { loadSwitches 5 } state OBJECT IDENTIFIER ::= { sw5 0 } loadCurrent OBJECT IDENTIFIER ::= { sw5 1 } loadPower OBJECT IDENTIFIER ::= { sw5 2 } hvdTrip OBJECT IDENTIFIER ::= { sw5 3 } lvdTrip OBJECT IDENTIFIER ::= { sw5 4 } fuseTrip OBJECT IDENTIFIER ::= { sw5 5 } sw6 OBJECT IDENTIFIER ::= { loadSwitches 6 } state OBJECT IDENTIFIER ::= { sw6 0 } loadCurrent OBJECT IDENTIFIER ::= { sw6 1 } loadPower OBJECT IDENTIFIER ::= { sw6 2 } hvdTrip OBJECT IDENTIFIER ::= { sw6 3 } lvdTrip OBJECT IDENTIFIER ::= { sw6 4 } fuseTrip OBJECT IDENTIFIER ::= { sw6 5 } sw7 OBJECT IDENTIFIER ::= { loadSwitches 7 } state OBJECT IDENTIFIER ::= { sw7 0 } loadCurrent OBJECT IDENTIFIER ::= { sw7 1 } loadPower OBJECT IDENTIFIER ::= { sw7 2 } hvdTrip OBJECT IDENTIFIER ::= { sw7 3 } lvdTrip OBJECT IDENTIFIER ::= { sw7 4 } fuseTrip OBJECT IDENTIFIER ::= { sw7 5 } sw8 OBJECT IDENTIFIER ::= { loadSwitches 8 } state OBJECT IDENTIFIER ::= { sw8 0 } loadCurrent OBJECT IDENTIFIER ::= { sw8 1 } loadPower OBJECT IDENTIFIER ::= { sw8 2 } hvdTrip OBJECT IDENTIFIER ::= { sw8 3 } lvdTrip OBJECT IDENTIFIER ::= { sw8 4 } fuseTrip OBJECT IDENTIFIER ::= { sw8 5 } cf0 OBJECT IDENTIFIER ::= { customFeeds 0 } value OBJECT IDENTIFIER ::= { cf0 0 } cf1 OBJECT IDENTIFIER ::= { customFeeds 1 } value OBJECT IDENTIFIER ::= { cf1 0 } cf2 OBJECT IDENTIFIER ::= { customFeeds 2 } value OBJECT IDENTIFIER ::= { cf2 0 } cf3 OBJECT IDENTIFIER ::= { customFeeds 3 } value OBJECT IDENTIFIER ::= { cf3 0 } cf4 OBJECT IDENTIFIER ::= { customFeeds 4 } value OBJECT IDENTIFIER ::= { cf4 0 } cf5 OBJECT IDENTIFIER ::= { customFeeds 5 } value OBJECT IDENTIFIER ::= { cf5 0 } cf6 OBJECT IDENTIFIER ::= { customFeeds 6 } value OBJECT IDENTIFIER ::= { cf6 0 } cf7 OBJECT IDENTIFIER ::= { customFeeds 7 } value OBJECT IDENTIFIER ::= { cf7 0 } cf8 OBJECT IDENTIFIER ::= { customFeeds 8 } value OBJECT IDENTIFIER ::= { cf8 0 } ts0 OBJECT IDENTIFIER ::= { tempSensors 0 } value OBJECT IDENTIFIER ::= { ts0 0 } ts1 OBJECT IDENTIFIER ::= { tempSensors 1 } value OBJECT IDENTIFIER ::= { ts1 0 } ts2 OBJECT IDENTIFIER ::= { tempSensors 2 } value OBJECT IDENTIFIER ::= { ts2 0 } ts3 OBJECT IDENTIFIER ::= { tempSensors 3 } value OBJECT IDENTIFIER ::= { ts3 0 } ts4 OBJECT IDENTIFIER ::= { tempSensors 4 } value OBJECT IDENTIFIER ::= { ts4 0 } ts5 OBJECT IDENTIFIER ::= { tempSensors 5 } value OBJECT IDENTIFIER ::= { ts5 0 } ts6 OBJECT IDENTIFIER ::= { tempSensors 6 } value OBJECT IDENTIFIER ::= { ts6 0 } ts7 OBJECT IDENTIFIER ::= { tempSensors 7 } value OBJECT IDENTIFIER ::= { ts7 0 } ts8 OBJECT IDENTIFIER ::= { tempSensors 8 } value OBJECT IDENTIFIER ::= { ts8 0 } pm0 OBJECT IDENTIFIER ::= { powerMetrics 0 } power OBJECT IDENTIFIER ::= { pm0 0 } voltage OBJECT IDENTIFIER ::= { pm0 1 } minVoltage OBJECT IDENTIFIER ::= { pm0 2 } maxVoltage OBJECT IDENTIFIER ::= { pm0 3 } amperage OBJECT IDENTIFIER ::= { pm0 4 } minAmperage OBJECT IDENTIFIER ::= { pm0 5 } maxAmperage OBJECT IDENTIFIER ::= { pm0 6 } realPower OBJECT IDENTIFIER ::= { pm0 7 } minRealPower OBJECT IDENTIFIER ::= { pm0 8 } maxRealpower OBJECT IDENTIFIER ::= { pm0 9 } powerFactor OBJECT IDENTIFIER ::= { pm0 10 } apparantPower OBJECT IDENTIFIER ::= { pm0 11 } frequency OBJECT IDENTIFIER ::= { pm0 12 } thd OBJECT IDENTIFIER ::= { pm0 13 } pm1 OBJECT IDENTIFIER ::= { powerMetrics 1 } power OBJECT IDENTIFIER ::= { pm1 0 } voltage OBJECT IDENTIFIER ::= { pm1 1 } minVoltage OBJECT IDENTIFIER ::= { pm1 2 } maxVoltage OBJECT IDENTIFIER ::= { pm1 3 } amperage OBJECT IDENTIFIER ::= { pm1 4 } minAmperage OBJECT IDENTIFIER ::= { pm1 5 } maxAmperage OBJECT IDENTIFIER ::= { pm1 6 } realPower OBJECT IDENTIFIER ::= { pm1 7 } minRealPower OBJECT IDENTIFIER ::= { pm1 8 } maxRealpower OBJECT IDENTIFIER ::= { pm1 9 } powerFactor OBJECT IDENTIFIER ::= { pm1 10 } apparantPower OBJECT IDENTIFIER ::= { pm1 11 } frequency OBJECT IDENTIFIER ::= { pm1 12 } thd OBJECT IDENTIFIER ::= { pm1 13 } pm2 OBJECT IDENTIFIER ::= { powerMetrics 2 } power OBJECT IDENTIFIER ::= { pm2 0 } voltage OBJECT IDENTIFIER ::= { pm2 1 } minVoltage OBJECT IDENTIFIER ::= { pm2 2 } maxVoltage OBJECT IDENTIFIER ::= { pm2 3 } amperage OBJECT IDENTIFIER ::= { pm2 4 } minAmperage OBJECT IDENTIFIER ::= { pm2 5 } maxAmperage OBJECT IDENTIFIER ::= { pm2 6 } realPower OBJECT IDENTIFIER ::= { pm2 7 } minRealPower OBJECT IDENTIFIER ::= { pm2 8 } maxRealpower OBJECT IDENTIFIER ::= { pm2 9 } powerFactor OBJECT IDENTIFIER ::= { pm2 10 } apparantPower OBJECT IDENTIFIER ::= { pm2 11 } frequency OBJECT IDENTIFIER ::= { pm2 12 } thd OBJECT IDENTIFIER ::= { pm2 13 } pm3 OBJECT IDENTIFIER ::= { powerMetrics 3 } power OBJECT IDENTIFIER ::= { pm3 0 } voltage OBJECT IDENTIFIER ::= { pm3 1 } minVoltage OBJECT IDENTIFIER ::= { pm3 2 } maxVoltage OBJECT IDENTIFIER ::= { pm3 3 } amperage OBJECT IDENTIFIER ::= { pm3 4 } minAmperage OBJECT IDENTIFIER ::= { pm3 5 } maxAmperage OBJECT IDENTIFIER ::= { pm3 6 } realPower OBJECT IDENTIFIER ::= { pm3 7 } minRealPower OBJECT IDENTIFIER ::= { pm3 8 } maxRealpower OBJECT IDENTIFIER ::= { pm3 9 } powerFactor OBJECT IDENTIFIER ::= { pm3 10 } apparantPower OBJECT IDENTIFIER ::= { pm3 11 } frequency OBJECT IDENTIFIER ::= { pm3 12 } thd OBJECT IDENTIFIER ::= { pm3 13 } pm4 OBJECT IDENTIFIER ::= { powerMetrics 4 } power OBJECT IDENTIFIER ::= { pm4 0 } voltage OBJECT IDENTIFIER ::= { pm4 1 } minVoltage OBJECT IDENTIFIER ::= { pm4 2 } maxVoltage OBJECT IDENTIFIER ::= { pm4 3 } amperage OBJECT IDENTIFIER ::= { pm4 4 } minAmperage OBJECT IDENTIFIER ::= { pm4 5 } maxAmperage OBJECT IDENTIFIER ::= { pm4 6 } realPower OBJECT IDENTIFIER ::= { pm4 7 } minRealPower OBJECT IDENTIFIER ::= { pm4 8 } maxRealpower OBJECT IDENTIFIER ::= { pm4 9 } powerFactor OBJECT IDENTIFIER ::= { pm4 10 } apparantPower OBJECT IDENTIFIER ::= { pm4 11 } frequency OBJECT IDENTIFIER ::= { pm4 12 } thd OBJECT IDENTIFIER ::= { pm4 13 } cc0 OBJECT IDENTIFIER ::= { chargeControllers 0 } batteryVoltage OBJECT IDENTIFIER ::= { cc0 1 } arrayVoltage OBJECT IDENTIFIER ::= { cc0 2 } chargeCurrent OBJECT IDENTIFIER ::= { cc0 3 } loadCurrent OBJECT IDENTIFIER ::= { cc0 4 } ambientTemp OBJECT IDENTIFIER ::= { cc0 5 } batteryTemp OBJECT IDENTIFIER ::= { cc0 6 } heatsinkTamp OBJECT IDENTIFIER ::= { cc0 7 } chargeState OBJECT IDENTIFIER ::= { cc0 8 } lastUpdate OBJECT IDENTIFIER ::= { cc0 9 } errorCode OBJECT IDENTIFIER ::= { cc0 10 } cc1 OBJECT IDENTIFIER ::= { chargeControllers 1 } batteryVoltage OBJECT IDENTIFIER ::= { cc1 1 } arrayVoltage OBJECT IDENTIFIER ::= { cc1 2 } chargeCurrent OBJECT IDENTIFIER ::= { cc1 3 } loadCurrent OBJECT IDENTIFIER ::= { cc1 4 } ambientTemp OBJECT IDENTIFIER ::= { cc1 5 } batteryTemp OBJECT IDENTIFIER ::= { cc1 6 } heatsinkTamp OBJECT IDENTIFIER ::= { cc1 7 } chargeState OBJECT IDENTIFIER ::= { cc1 8 } lastUpdate OBJECT IDENTIFIER ::= { cc1 9 } errorCode OBJECT IDENTIFIER ::= { cc1 10 } cc2 OBJECT IDENTIFIER ::= { chargeControllers 2 } batteryVoltage OBJECT IDENTIFIER ::= { cc2 1 } arrayVoltage OBJECT IDENTIFIER ::= { cc2 2 } chargeCurrent OBJECT IDENTIFIER ::= { cc2 3 } loadCurrent OBJECT IDENTIFIER ::= { cc2 4 } ambientTemp OBJECT IDENTIFIER ::= { cc2 5 } batteryTemp OBJECT IDENTIFIER ::= { cc2 6 } heatsinkTamp OBJECT IDENTIFIER ::= { cc2 7 } chargeState OBJECT IDENTIFIER ::= { cc2 8 } lastUpdate OBJECT IDENTIFIER ::= { cc2 9 } errorCode OBJECT IDENTIFIER ::= { cc2 10 } cc3 OBJECT IDENTIFIER ::= { chargeControllers 3 } batteryVoltage OBJECT IDENTIFIER ::= { cc3 1 } arrayVoltage OBJECT IDENTIFIER ::= { cc3 2 } chargeCurrent OBJECT IDENTIFIER ::= { cc3 3 } loadCurrent OBJECT IDENTIFIER ::= { cc3 4 } ambientTemp OBJECT IDENTIFIER ::= { cc3 5 } batteryTemp OBJECT IDENTIFIER ::= { cc3 6 } heatsinkTamp OBJECT IDENTIFIER ::= { cc3 7 } chargeState OBJECT IDENTIFIER ::= { cc3 8 } lastUpdate OBJECT IDENTIFIER ::= { cc3 9 } errorCode OBJECT IDENTIFIER ::= { cc3 10 } END