bin.fromArray()

bin.fromArray(array, format, [byteOrder]) → buffer

Packs an array of numbers or bits into a binary buffer.

Packs an array into binary data. For bit types ("BITS"/"RBITS") the array holds 1/0 (or true/false) entries — 16 bits pack into two bytes. The inverse is bin.toArray().

Arguments

NameTypeRequiredDefaultDescription
array array yes Values to pack — numbers, or 1/0 / true/false for bit types.
format string yes Element type: "F32", "F64", "BITS", "RBITS", "U8", "S8", "U16", "S16", "U32", "S32".
byteOrder string optional "ABCD" Byte order, e.g. "AB", "ABCD", "BADC", "DCBA", "CDAB". Not used by bit types.

Returns

buffer Packed binary data ready for modbus.write(), mqtt.publish() or hex conversion.

Example

let data = bin.fromArray([1,2,3,4,5,6,7,8], "U16", "AB");
modbus.write(0, 1, 16, 0, 8, data);

// pack floats, word-swapped
let bytes = bin.fromArray([12345.6789, 100, 200], "F32", "BADC");

// pack a bit array (two bytes)
let flags = bin.fromArray([1,0,0,0,0,0,0,0, 0,1,1,1,1,1,1,1], "RBITS");