📦 Archived documentation: r1 (committed 2026-10-07) View current documentation →
Available on: Flexs Q5C

scope.getPeak()

scope.getPeak(fMin, fMax, [label]) → { bin, freq, amp }

Finds the highest-amplitude peak in a frequency range of the most recent FFT — typically used to measure running speed.

Searches the spectrum of the most recent scope.getWaveform() capture between fMin and fMax and returns the dominant peak.

The optional label string draws a named marker on the FFT amplitude chart in the web interface for the associated capture, which makes verifying the speed lock-on easy.

Measuring RPM. Search a window around the expected electrical or mechanical frequency, then convert. For a 10-pole motor near line frequency:

let speed = scope.getPeak(50, 70, "hz");
let rpm = speed.freq * 120 / 10;

For better precision, re-find the speed on a strong harmonic using a tight tolerance window seeded from the first estimate:

let peak180hz = rpm/60*15;
let speed = scope.getPeak(peak180hz*0.98, peak180hz*1.02, "Speed"); // ±2%
rpm = speed.freq * 4;

Arguments

NameTypeRequiredDefaultDescription
fMin number (Hz) yes — Lower bound of the search window.
fMax number (Hz) yes — Upper bound of the search window.
label string optional — Optional marker label shown on the FFT chart for this capture.

Returns

object { bin, freq, amp } — e.g. {"bin":322,"freq":59.977173,"amp":0.037552}

Example

scope.getWaveform({ "ch":0, "osr":4096, "size":4096, "fft":true,
  "bandpass":false, "fMin":120, "fMax":190, "demod":false, "demodRatio":8 });

let speed = scope.getPeak(50, 70, "hz");
print(string(speed)); // {"bin":322,"freq":59.977173,"amp":0.037552}
let rpm = speed.freq * 120 / 10; // 10-pole motor